Utilizing Clinical Information for QMSR Compliance and Product Improvement

Share this article!

On February 2, 2026, the FDA will require that all medical devices sold in the United States intended for human use be developed and maintained via a process compliant with the new Quality Management System Regulation (QMSR). QMSR is an update to the FDA’s long-standing Quality System Regulations (QSR), which are requirements put in place to ensure the safety and efficacy of medical devices.(1) The QSR outlines procedures for design controls, production processes, and quality assurance to protect public health and encourage the development of new medical devices.(2) This regulation provides a foundation for achieving quality within the organization. However, with the introduction of the QMSR, the FDA has sought harmonization with global standards, specifically ISO 13485:2016 Medical Devices – Quality Management Systems – Requirements for regulatory purposes. ISO 13485:2016 is a globally recognized quality management system standard for organizations involved in the design, development, production, installation, and servicing of medical devices and is intended to ensure that they meet customer and regulatory requirements. The standard takes a risk-based approach to product compliance that is meant to enhance the safety of medical devices. The FDA’s alignment with ISO 13485 highlights the importance of a robust quality management system throughout a device's lifecycle. Within this framework, clinical data emerges as a critical component for demonstrating compliance and driving product development. For companies that develop and manufacture medical devices, clinical data can be used as a valuable tool for creating products that are safe and effective. It offers real-life evidence that can be used to guide design decisions, assess risks, and inform improvements throughout the lifecycle of the device. Clinical data acts as a window into the real world, allowing medical device manufacturers visibility into how their products are actually used and how they impact their patients. It helps them understand what users truly need while identifying areas for improvement and increased patient safety. This article will discuss how clinical data can be leveraged for QMSR compliance, focusing on design controls, risk management, and post-market surveillance.

Clinical Data in Product Development

Clinical data can offer manufacturers several benefits when used during the product development process. This data, found in several forms, such as published studies, customer feedback, and regulatory agency data, can provide manufacturers with real-world evidence that can lead to the enhancement of product design and the identification of areas of improvement. Some examples of this are below:

1. Identifying Areas for Product Enhancement: Clinical data from published studies can be used to gather information on user requirements and improve patient outcomes. By analyzing clinical literature, manufacturers are able to better understand the user’s experiences, performance problems, and unmet clinical needs, which can guide product improvement efforts.

Example: When analyzing clinical studies on an insulin pump, a company learns that users of the product often experience difficulties with the device’s user interface. This leads to errors in the dose of insulin administered. This insight prompts the manufacturer to redesign the user interface by simplifying the menu structure and improving the clarity of on-screen instructions. This enhancement results in a more user-friendly device, reduces errors, and improves patient outcomes.

2. Supporting Design Changes: Clinical literature can provide a valuable foundation for making design modifications that improve device efficacy and usability, address identified risks, and enhance patient outcomes.

Example: A manufacturer of scalp cooling devices that are used to prevent hair loss during chemotherapy analyzes clinical data that reveals that while the device is effective for some types of cancer, patients with specific solid tumors have lower success rates. This real-world evidence supports a design modification to the device’s cooling cap, which improves the fit of the device on the patient’s scalp. In addition to potentially increasing the efficacy of the device, this design change could increase the number of patients who can benefit from the device.

3. Generating New Product Ideas: Clinical data can be informative and may lead to new product ideas. Clinical literature might introduce a manufacturer to new technologies, new ways of treatment, or new features that benefit their user base. Clinical studies can be an excellent source of creativity and inspiration.

Example: A manufacturer of endovascular grafts for aortic aneurysm treatment analyzes clinical literature and discovers a high rate of complications associated with graft migration in patients with challenging aortic anatomies. This leads to the development of a novel graft with an integrated anchoring system. This new design incorporates small, biocompatible anchors that gently attach to the aortic wall thus preventing its migration and increasing the stability over a long period. This innovation, grounded in clinical data, improved the safety and efficacy of the endovascular aneurysm repair.

4. Supporting Regulatory Submissions: Scientific literature can be used to support FDA regulatory submissions, including supplements to post-market approvals (PMAs), product development protocols (PDPs), and Humanitarian Device Exemptions (HDEs). Manufacturers can refer to data from published clinical studies in their submissions to demonstrate the safety and efficacy of a device and demonstrate that valid scientific evidence exists.

Clinical Data in the Design Control and Risk Management

The QMSR design control process requires a risk-based approach in which manufacturers are expected to identify and manage risks throughout the product life cycle. The process includes several key stages, starting with the identification of user needs and intended use, followed by design planning, design input, design output, design review, design verification, design validation, design transfer and design changes. Each stage involves documented procedures and activities meant to ensure that the design outputs are in agreement with the design inputs and the product is safe, effective and appropriate for the intended purpose. Clinical literature can serve as a source of information and evidence that is used in the process of developing, verifying, and validating the medical device. Clinical literature can support the design control process in the following ways:

1. Planning Stage: Clinical literature can provide a knowledge base for the initial planning phase of the design control process. It can be a source of information on the medical condition, patient population, and the existing treatment options. Real-world data in the form of clinical studies can be utilized to understand the clinical needs, patient outcomes, and regulatory requirements relevant to the device under

Example: A company that is developing a new type of prosthetic heart valve gathers detailed information from clinical literature about heart valve disease, patient characteristics, surgical techniques, and outcomes of current valve replacements. The information collected helps in the planning stage to determine the design features, choice of materials, and clinical trial design to ensure the new device addresses the needs of the target population and improves patient outcomes.

2. Design Input: Manufacturers can identify clinical parameters, performance metrics, as well as safety features that guide the development of the device by examining published studies, trials, and real-world evidence. Design inputs that are derived from clinical literature can help ensure the device meets the needs of the patients and health care professionals as well as regulatory standards.

Example: A manufacturer is developing a continuous glucose monitor (CGM) and decides to examine published studies and real-world evidence to understand the accuracy, user-friendliness, and safety of the CGMs already on the market. From their research, they find that existing CGMs have a mean absolute relative difference (MARD) between 9-10%. As a result of this discovery, they established a design input that requires the CGM they are developing to have a MARD of less than 7%. This will help ensure their new CGM is more accurate than existing CGMs and that they meet the needs of patients and healthcare providers.

3. Design Verification and Validation: Clinical literature can also help demonstrate that the device meets its specifications and intended use requirements during the verification and validation process. Manufacturers can refer to clinical data when they are establishing acceptance criteria, conducting performance tests, and validating the safety and efficacy of the device. Referencing clinical literature ensures the device will work as intended in real-world clinical settings and meet regulatory expectations.

Example: Verification and validation activities were carried out by the manufacturer of an esophageal cooling device to confirm that it had the capabilities of meeting its design specifications and performing as intended in the clinical setting. The manufacturer looked to clinical literature on therapeutic hypothermia to help define the parameters and acceptance criteria for these tests. This data helped to determine the optimal cooling temperature range required to prevent clinical outcomes such as neurological damage after cardiac arrest. This data was used to establish testing limits for target temperature and temperature fluctuations. The clinical literature also assisted in the selection of appropriate endpoints for the assessment of the device’s effectiveness, for instance, patient survival rate, neurological outcomes, and length of stay in the hospital. Using clinical literature as a reference, the manufacturer was able to design testing that reflected real-world clinical practice and ensure that the device met its design specifications and intended use requirements.

4. Risk Management: Clinical literature can be utilized to identify and evaluate risk during the design process. It can be used to uncover potential hazards, patient safety concerns, and adverse events associated with the use of a medical device. This incorporation of clinical data into the risk management process helps manufacturers develop more efficient risk mitigation strategies throughout a device’s lifecycle.

Example: When developing an esophageal cooling device, manufacturers determine that esophageal thermal damage may occur with the use of the device. To reduce this risk, they referred to clinical practice guidelines that stated that exposure to extreme temperatures for long periods could lead to tissue damage. This information was used by the manufacturer to integrate a temperature control and monitoring system into the device. This system provides real-time monitoring of the esophageal temperature and regulates the cooling or heating process to ensure that the temperature is within the safe and effective range, thereby reducing the risk of thermal injury to the esophagus.

5. Design Transfer and Design Changes: During design transfer and design change activities, clinical data can provide real-world evidence to ensure that the device is manufactured to the correct quality and regulatory standards. Furthermore, clinical literature can help identify areas of improvement in the design of the products by being a source of information on user feedback, clinical outcomes, and performance data.

Example: A manufacturer of automated external defibrillators (AEDs) reviewed clinical literature and noted that rescuers in emergency situations have difficulty with the placement of the AED electrode pads, particularly in stressful situations. This results in delays in the delivery of the defibrillation shocks. The manufacturer used this information to redesign the AED to include upgraded visual cues and tactile guides on the device itself to allow for easier electrode placement, thereby reducing the risk of errors during use. This design change, informed by clinical literature, enhances the AED’s usability and improves the probability of successful resuscitation.

In summary, clinical literature offers support at each stage of the QMSR design control process. Integration of clinical data into the design and development of medical devices can help manufacturers accurately align their medical devices with patient needs, regulatory requirements, and quality standards to deliver safe, effective, and reliable devices. This leveraging of this type of clinical evidence cultivates a culture of innovation, continuous improvement, and patient-centered care in the medical device industry.

Post-Market Surveillance Data in QMSR Compliance

Post-market surveillance data provides real-life information about device performance, safety, and efficacy. There are several types of post-market surveillance data, including active surveillance, passive surveillance, literature reviews, customer feedback, and regulatory product database search results. This data enables manufacturers to identify and mitigate potential risks and ensure compliance with the QMSR. Data extracted from regulatory databases such as the FDA’s Manufacturer and User Facility Device Experience Database (MAUDE), the United Kingdom Medicine &Healthcare Product Regulatory Agency Database, and Health Canada’s Recalls and Safety Database provide information reported to regulatory agencies about adverse events and device malfunctions. The proactive analysis of this information helps manufacturers identify potential safety concerns, assess the efficacy of risk management measures, and undertake the necessary corrective actions.

In conclusion, leveraging clinical data can be beneficial to a manufacturer’s medical device development process and can help achieve and maintain compliance with QMSR requirements. The first step to identifying literature is to plan and execute a focused literature search and review process. Search terms and inclusion/exclusion criteria must be clearly defined with the objective of selecting literature that addresses the needs of the manufacturer.

How Can Nerac Help?

Nerac offers comprehensive support in navigating the complexities of QMSR compliance by providing expert medical data analysis and targeted clinical literature services. Our team of specialized medical data analysts excels in conducting focused literature searches and reviews, helping medical device manufacturers like yours enhance their literature review processes and post-market surveillance efforts to ensure ongoing product safety, efficacy, and compliance. Our solutions are specifically designed to:

  • Conduct comprehensive literature reviews: Streamline your process of identifying and analyzing the most relevant clinical studies, and regulatory data, ensuring your product improvements are backed by the latest evidence.
  • Optimize post-market surveillance: Improve your ability to track, analyze, and act on real-world data, identifying any emerging safety concerns or areas for product enhancement that might impact compliance.

With Nerac, you can access the expertise and tools needed to ensure your products meet stringent regulatory requirements while fostering continuous product improvement and patient-centered care.

About the Analyst

Miriam Sharif-Murray, M.S.

Miriam Sharif-Murray brings over 20 years of medical device/regulatory experience to Nerac clients. After completing her degrees, she worked as a chemist for chemical and medical device manufacturers where she further strengthened her scientific knowledge and built her expertise in the regulatory environment.

Academic Credentials

  • M.S., Biology, Tennessee State University
  • B.A., Biology, Fisk University

References

1. ADMINISTRATION UFAD. Medical Devices; Quality System Regulation Amendments. Federal Register [Internet]. 2024 February 5, 2025; 2025(89(22)):[6494-546 pp.]. Available from: https://www.federalregister.gov/documents/2024/02/02/2024-01709/medical-devices-quality-system-regulation-amendments.

2. Food and Drug Administration DoHaHS. Title 21 - Food and Drugs. CHAPTER 1 - FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES. SUBCHAPTER H - MEDICAL DEVICES. PART 820 - QUALITY SYSTEM REGULATION Electronic Code of Federal Regulations (eCFR)2025 [cited 2025 February 5]. Available from: https://www.federalregister.gov/documents/2024/02/02/2024-01709/medical-devices-quality-system-regulation-amendments.